Bobcat 773 U1112-08 Error Code
U1112-08 Error Code
Lift Arm Angle No Communication is the main cause of U1112-08 error.This code can lead to engine failure if the issue is not addressed. Working with a maintenance professional is crucial in order to review and address signs of overheating on your vehicle. In the long term, this can prevent failure at a critical time.
Tip For 773 Model
If the engine stops, the boom / bucket
(attachments) can be lowered to the ground
using hydraulic pressure in the accumulator.
The control console must be in the locked
down position, and the key switch in the ON
position.
Use the control lever to lower the boom.